The nema 250 standard is available from ihs, ansi, and techstreet. There was no trace of dust or water visible inside the enclosures. The requirements of iec 60529 testing are identical to those detailed in en 60529 testing. These, in turn, summarise the scale of protection offered from estranged. Technical application guide ip codes in accordance with. The us ansi american national standards institute and nema national electrical manufacturers association are members of iec iec 60529 and contributed to its development. This standard has been reproduced from iec 60529 ed 2. International electrotechnical commission iec page count. Within this standard it outlines an international classification system to test the sealing effectiveness of enclosures of electrical equipment against the the equipment of solid particles and liquid. Each test in iec 60529 ingress protection testing specifies parameters. F2 labs is accredited to perform ingress protection ip testing to iec standard 60529, nema 250 testing, and ul 50e testing. Ipx9k and ip9k rain test chamber iso20653 iec 60529.
For ipx8, the eut is immersed in water 1 m above from the bottom of enclosure. Test report iec 60529 en 60529 degrees of protection. Degrees of protection provided by enclosure asnzs 60529 ip. International electrotechnical commission iec standard 60529 the iec is the worlds leading organization. Iec 60529 ip rating sometimes is referred to as ingress protection. Iec standards often have multiple subpart documents. Testing for ingress protection of portable electronic devices.
Connectors and contacts are tested to environmental and mechanical stress to determine if the product still functions properly. An ip of three means ip ingress protection against solid objects greater than 2. Used for the inspection of electronic products with iecip supplementary code enhancement test, comply with the test standards such as. Enclosures rated four offer protection from items that are solid objects greater than one mm.
F2 labs can assist you in testing your electrical products to the applicable iec standards. For ip code water testing, the duration, flow rate, temperature, depth and angle of the water is spelled out. The ip codes refer only to protection against contact and the penetration of solid foreign objects and dust marked. Testing for ingress protection of portable electronic. If the ip code is not stated, then the electrical equipment is protected in accordance with ip20. Advantages to the luminaire manufacturer in utilizing the iec 60529 standard are as follows. Within this standard it outlines an international classification system to test the sealing effectiveness of enclosures of electrical equipment against the the. The requirement is that the equipment under test eut, shall experience no harmful effects from the dripping water. Degrees of protection provided by enclosures ip code. Used for the inspection of electronic products with iec ip supplementary code enhancement test, comply with the test standards such as. Ingress protection ip testing in accordance with iec 60529. Quest engineering solutions has the capability to perform ip ingress protection, also referred to as intrusion protection testing per numerous standards, including iec 60529. Although the iec 60529 defines specific levels of protection, the testing protocols are limited and do not account for realworld condi tions that portable electronics. Mar 18, 2020 iec 60529 1 pdf iec degrees of protection provided by enclosures ip code.
Testing the sealing of the enclosure against solids is done by the use of spheres of specific diameters 50, 12. All equipment fully complies with iec 60529 ip code standard and all other international standards with similar tests. Ingress protection ip testing quest engineering solutions. Electrotechnology enclosure testing iec 60529 and nema 250. International standard iec 60529 has been prepared by technical committee. Ip testing procedure electrical safety testing laboratory. The iec is the worlds leading organization for the preparation and publication of international standards for all electrical, electronic and related technologies. Ingress protection ip testing performance testing against water and dust ingress.
In the iec 60529 impact tests are no longer defined. Performance of iec 60529 testing degree of protection offered by enclosure ip code generally speaking. The nema 250 and iec 60529 standards are internationally recognized electrotechnology enclosure tests. Can the testing used to determine an iec 60529 ip rating be correlated to nema dust and water performance testing. Ul offers complete testing and certification services for street and roadway luminaires to iec 6059823 ik ratings are defined as ikxx, where xx is a number from 00 to 10 indicating the degrees. Ip tests according to iec en 60529, din 40 050 or iso 20653. Ingress protection tests are conducted in accordance with iec 60529. It is published by the international electrotechnical commission iec. Technical application guide ip codes in accordance with iec 60529. The test is performed for 24 hr or as per manufacturer demand. Iec 60529 is an international standard designed to give products a determined international protection marking according to the ip code rating. Definition of protection grades iec 60529 hammond mfg. Strikethrough example identifies iec text, tables and figures which, for the purposes of this australian standard, are deleted.
Ingress protection ip testing laboratories element. Experior laboratories can conduct iec 60512 testing of connectors for electronic equipment. Our technical experts in iec test standards can assist your company in to illustrate, a piece of electronic equipment rated ipx7 will almost certainly. An international committee the international electrotechnical commission defined this standard originally in 1998.
For example, the size of the solid particle can vary based on the rating. Ip x1, ip x2 and ip x3 are also performed in the lab. Defined as dripping water with vertically falling drops. Iec 6059823 is the international standard for luminaires for road and street lighting. Have ip ratings explained in this handy guide, including potential impact on your business. Nema does not certify, test or inspect products, designs or installations. The first digit indicates protection against ingress of solid foreign objects. This testing is designed as a means to verify that your products internal components are adequately sealed and protected from the intrusion of foreign objects.
Particulate testing iec standard 60529 testing protocols evaluate materials based on their. How do the water test parameters compare between nema 250 hose testing and iec 60529 ip hose testing. Our technical experts in iec 60529 test standards can assist your. Cei en 605291997 international protection ip en 60529 f irst n umeral protection against solid bodies 0 no protection second n umeral protection against liquids 1 obect equal to or greater than 50 mm 1 vertically dripping water 2 obect equal to or greater than 12,5 mm 2 75 to 105 angled dripping water 3 obect equal to or greater. This indian standard which is identical with iec 60529. Iec 60529 ip testing ingress protection testing if your products are going to be exposed to multiple environments whether it be indoors or outdoors, you may want to consider ingress protection testing to determine their susceptibility to particle sand and dust or water ingress. The standard we most commonly use at itc for ingress protection is bs en 60529 and iec 60529. It is used for consumer safety and enclosure testing. Performance testing against water and dust ingress. Iec 60529 enclosure buyers beware overall conclusions. The degree of protection ip does not need to be tested for enclosure already tested to iec 62208. An ip certification rating table or chart, has been constructed by the international electrotechnical commission iec for international use. Although ingress protection ip testing is voluntary, specifiers and purchasers often request an ip rating in order to verify your lighting products acceptability for use in outdoor or industrial applications. Ip tests according to iecen 60529, din 40 050 or iso 20653.
Tuv nord cert testing of degrees of protection provided by enclosures acc. We can provide you with the necessary iec 606011, iec 6060112, and more testing and certifications to. Reproducible but contains colour pages, advise dispatch. The iec 60529 standard determines how well a products enclosure protects internal working parts from ice, dust, water, and intrusion by hands, fingers, tools, and wires. This second edition of iec 60529 takes account of experiences with the first edition, and clarifies the requirements. The iec 60529 test standard considers a rating of two as protection from solid objects greater than 12.
The ip code, or ingress protection code, iec standard 60529, sometimes interpreted as international protection code, classifies and rates the degree of protection provided by mechanical casings and electrical enclosures against intrusion, dust, accidental contact, and water. We can also provide ez test plans for ingress testing. Tuv nord cert testing of degrees of protection provided by. This results in two challenges for the portable electronics industry. Ingress protection ip testing per bs en 60529, iec 60529 for lighting products itc india providing ip ingress protection testing per bs en 60529, iec 60529 for lighting products. Download iec 60529 degrees of protection provided by enclosures ip code rar from 2 mb, iec 60529 degrees of protection provided by enclosures ip code pdf from 2 mb free from tradownload. This is an incomplete list of standards published by the international electrotechnical commission iec the numbers of older iec standards were converted in 1997 by adding 60000. All the engineers really enjoy this video that dell made, regarding ip code testing. The requirements and related tests of this standard cover. It has the status of a horizontal standard in accordance with iec guide 104. Below is a brief description of the two types of dripping water tests included in ingress protection testing from iec 60529. Evaluate the degree of protection provided by a products enclosure with ingress testing from intertek. The degree of protection ip does not need to be tested for enclosure already tested to. This standard tests the sealing effectiveness of enclosures of electrical equipment against the intrusion of solid particles and liquid.
For products to be officially released with an ip rating they need to be tested by certified laboratories which perform the tests in accordance with the iec 60529 standard. Use the table below to find products that comply with a specific ip code test. Global enclosure standards the three most globally recognized standards for enclosures are. General examination,dimensions and performance testing is conducted as well. Iec 60598 was created for luminaire testing and it is clear that iec 60529 is a less stringent standard, and should never be considered an equivalent to iec 60598. Testing for explosionprotection technique it is important to recognise that, before an ex enclosure is tested for ip code, the order of tests laid down in the general requirements standard iec 600790 or iec 612410 must be followed. As 605292004 degrees of protection provided by enclosures. Ingress protection ip testing iec 60529 testing f2 labs. The nema 250 standard has correlation tables for this. Both ul testing and ip testing are typically performed on enclosures to determine the level of protection they provide against water, dust, ice, etc. This includes the impact test and materials tests that are relevant to the enclosure. For ipx7, the eut is fully immersed in water at level of 150 mm excluding the height of the sample.